Apdu command responses. For each possible OATH command, there will be a class that knows how to build the command APDU and parse the data in the response APDU. 4 Coding conventions for command headers, data fields and response trailers. Response body . Follow edited Aug 14, 2018 at 22:55. This command-response message pair is known as an Application Protocol Data Unit (APDU). We need to know at least the specification of the protocol to understand the returned status word (unless somebody guesses it from the given data). A command APDU is sent by the reader to the card – it contains a mandatory 4-byte header (CLA, INS, P1, P2) and from 0 to 255 bytes of data. A088 0000 10 Parse APDU hex bytes into descriptions. EMVIntegrated Circuit Card Specifications for Payment Systems. FF 86 00 00 05 01 00 06 60 00 response - 6982 Security status not satisfied (not authenticated) I also tried APDU commands from other similar posts but all are giving same response. by Le. Send apdu by iccTransmitApduLogicalChannel and get String response Android App destroy must close channel by iccCloseLogicalChannel P. A command-response pair is formed by sending a command, processing it in the receiving The APDU message contains two parts: the Command APDU and the Response APDU. Card responds with 6985. \. However, when I send the APDU's command to mfrc630, I can't response anything. Modified 7 years, 4 months ago. The Response APDU can be either an Acknowledgment (called an ACK), which indicates that the most recent APDU was received successfully, or it can be a Negative Acknowledgement (called a NAK), which The terminal creates and sends a command to the smart card, which then interprets the command and sends a response. To do that, let’s An APDU is an Application Protocol Data Unit, a TPDU a Transport Protocol Data Unit. and getting '90' '00' as response which means my authentication is done. The UsbManager class I'm trying to send a VERIFY (pin) command using javax. NV A. @Micheal ,I'm not getting any result and app is crashing when I sent the APDU command which you suggested, but when I sent the above APDU i get a response as 6A80. Using the “Read binary” command on the selected Hi, We are testing the ST25R3916 to read Mifare 1K classic UID's. Original PIN: 1574 As far as I know, to open/close a logical channel we must use MANAGE CHANNEL APDU command. Viewed 15k times. Expected response data)? Here's the "long" version of my request: On the Java Card, I'm using both standard and custom APDU commands, and I can successfully invoke these commands using a python script (with the smartcard library). 5 Smart card : Get certificates content with APDU commands. but allows to send APDU-s from command line with opensc-tool -s XX:XX:XX:XX; Countless other apdu/script tools :| written in different languages Get Data APDU command different tags and response format. The Command APDUs are defined in ISO 7816-4, the format of an APDU Command is shown in Figure 3 No response data) and Case4Short (Command data. info on-site APDU Command/Response traces parsing. Hot Network Questions Theory of truth involving a virtual omniscient being The commands are unknown to me (0xF0 and 0xF1 are no MIFARE SAM commands). C) APDU Commands vs Pseudo APDU. S - I implemented "Seek for android" - org. ; Then send the APDU 80CA 2F00. T4TOPType 4 Tag Operation. Field name Length Description; Response data: I found that this should be the APDU command to get a card ID. 2 for both of this responses and finally I found nothing but the meaning of them! Note-2: When I change key set number to 2 , And set the radio button on add , I receive 6A80 [Incorrect DEBUG: Response APDU: 00 00 03 12 63 00 07 BB 03 00 FF 01 DA 26 EF 49 10 B7 72 00 9A 24 7F B4 A0 1F C7 C8 90 00 INFO: INITIALIZE UPDATE Successful DEBUG: Command APDU: 84 82 00 00 10 D5 41 CE BE F4 A8 E4 DD 36 6C C5 3E 19 9C 77 93 DEBUG: Response APDU: 90 00 DEBUG: Command APDU: 84 82 00 00 08 D5 41 CE BE F4 A8 E4 DEBUG: Command APDU: 00 A4 04 00 08 A0 00 00 00 03 00 00 00 DEBUG: Response APDU: 6F 10 84 08 A0 00 00 00 03 00 00 00 A5 04 9F 65 01 FF 90 00 Successfully selected Security Domain OP201a A0 00 00 00 03 00 00 00 DEBUG: Command APDU: 80 50 00 00 08 7F 41 A9 E7 19 37 83 FA DEBUG: Response APDU: 00 00 11 60 01 00 8A 79 0A F9 The commands 9x 20 are part of the lower ISO 14443-3 protocol and used during anticollision and activation of a card. One possible authentication APDU can be: {FF, 88, 00, 01, 60, 00} ). Viewed 3k times 0 When I am tryi ng to get the response by using (A0 C0 00 00 1A)GET RESPONSE command, I am getting SCardTransmit Failed! (80100008) The data buffer to receive returned data is too small for the returned data. 1 specification. Now i am trying to fire delete command to delete . 2. In fact, you I am trying to use UPDATE BINARY command using APDU command for modify IMSI code, but The response is 98 04. 18. 10. Modified 8 years, 4 months ago. GET RESPONSE APDU Command. Sign in to site. In the Verify I am done with Mutual Authentication Command : a) Initialize update . ExtendedLength interface. This class optionally supports extended length fields but only when the currently selected applet implements the javacardx. APDU ={0x00, 0xA4, 0x04, 0x00, 0x07 ,_data 7byte,0x00} // Commend[13byte] I think about that I get the data with 0x90, 0x00 but I can't take a response. The card will execute the command and send a response APDU back to the terminal. Asked 8 years, 4 months ago. In figure 5 a typical APDU command and response structure is I'm sniffing the IO line between a SIM card and an LTE module. Thanks for contributing an answer to Stack Overflow! Please be sure to answer the question. This class does not attempt to verify that the APDU encodes a semantically valid command. Note-1: I searched GP Card Spec2. New comments cannot be posted to this locked No response data) and Case4Short (Command data. 3 Response APDU In response to this command the card will send you a list of application IDs (AIDs) that it supports. Hence, you can't use these command codes in APDUs. Here is my command APDU: 00 A4 04 00 0E 32 50 41 59 2E 53 59 53 2E 4 An APDU is an Application Protocol Data Unit, a TPDU a Transport Protocol Data Unit. Users can change these commands in the provided software with SDK. This is case 4 in ISO 7816, command data and Le present. For the APDU command the byte array has to be (5 + AID. new byte[]{0002} will give you a byte array with one byte of value 2. 1 Case 1. LE has a value of 1 I have met the issue of response from APDU. Please sign in to comment. This method sets the logical AND of the bits already present in the card with the bits given in the command APDU (logical erased state of the bits of the file is 1), the one-time write in the card of the bits given in the Command APDU. Command header I Command body CLA INS PI P2 L, field The secured response APDU is as follows. In fact its syntax differs from the one specified for other APDU commands accepted by apdutool, as Lc is replaced by the expected response lenght, i. " Please, help, what's wrong with my command? The header contains the command code and the instruction code, while the body contains the data that is being sent. \java_card_kit-2_1_2\samples\classes\com\sun\javacard\s amples\HelloWorld\javacard\HelloWorld. I checked the RATS's response. Selecting the NFC NDEF file. into(); assert_eq! No response data) and Case4Short (Command data. 4 Problems coding an APDU command to verify PIN. I guess the command is as follows. The rest is the AID of the passport (5 bytes RID of ICAO, the Table 1 we summarize the complete digital signa- ture process in terms of the exchanged APDU commands and responses for a digital signature SC using the In- crypto microprocessor. Appendix B. 0. A088 0000 10 Introduce of iso8583. ; JSON Output: Outputs the parsed APDU data in JSON format for easy readability and integration with other tools. MIFARE DESFire does not return any response data to the ISOExternalAuthenticate command. Clause 10. There are two kinds of APDU: Command; Response; The 10 Structure of commands and responses. This specifies class coding, secure 该命令APDU的指令参数,如指明文件偏移地址以在偏移地址处写入数据 L c: 0, 1 或 3 指明命令APDU中携带的数据(Command data)字节数(N c) Command data N c: N c 字节的数据 L e: 0,1,2或3个 指明预期响应数据的最大字节数(N e) 响应APDU Response data N r (最大为N e) 响应数据 SW1-SW2 Your response code [106, -126] is better represented as hexadecimal, rather than implying any signed values. A088 0000 10 DEBUG: Response APDU: 00 00 03 12 63 00 07 BB 03 00 FF 01 DA 26 EF 49 10 B7 72 00 9A 24 7F B4 A0 1F C7 C8 90 00 INFO: INITIALIZE UPDATE Successful DEBUG: Command APDU: 84 82 00 00 10 D5 41 CE BE F4 A8 E4 DD 36 6C C5 3E 19 9C 77 93 DEBUG: Response APDU: 90 00 DEBUG: Command APDU: 84 82 00 00 08 D5 41 CE BE F4 A8 E4 Clause 7 specifies APDU commands and responses for transmission-oriented interindustry commands. Each APDU is processed and returned to apdutool, which displays both the command and response APDUs on the console. These commands are contained inside APplication Data Units (APDUs). 0 Getting originality signature from Mifare Ultralight card using an AC/SC reader APDU - AEIPS, APDU command/response parser at iso8583. The UICC may return any number of bytes in the range 1 to 256. No matter which APDU Command i send. I will then add it to the list. pdf), Text File (. 1 Command APDU 5. General Definitions I am trying to use run gsm algorithm command using RUIM tool. For example you can change the color of the LED, or delay Try authenticating with command 88 instead of 86, and then read the block. So, when I launched the following APDU command, I've obtained the content of my certificate: SELECT FILE : 00 A4 00 0C 02 B0 01. 2 Conditional usage and security APDU - EMV, APDU command/response parse at iso8583. APDU Sender Contactless is an application that allows you to send an ISO7816-4 C-APDU command using wireless technology NFC, and show the card's response. Code Issues Pull requests STM32 NFC NXP MFRC630, CLRC663, ISO14443A, ISO14443A-4, ISO7816-4 APDU This APDU selects a DESFire Application by it’s three byte DESFire Application Identifier (DESFire AID). Here are results with EMV APDU command/response APDU - Type 4 Tag Operation (T4TOP), APDU command/response parse at iso8583. - GitHub - jmarroyo/ApduSenderContactLess: APDU Sender Contactless is an application that allows you to send an ISO7816-4 C-APDU command using wireless technology NFC, and show the card's I'm testing APDU commands transmitting, and I've found a strange issue, for GET DATA command 00:CA:7F:68 I receive an error: 6D00: "Instruction code not supported or invalid" What can be the pr APDU Message Command-response Pair. I thought I know it but actually I don't. D:\3-TestTools\SmartCard>GP -list -d -v -i and gives this as a response: 48 65 6C 6C 6F 20 44 65 73 6B 74 6F 70 21 ("Hello Desktop!" when interpreted as ASCII) (Note that this response is not a valid response APDU according to ISO 7816-4 as it lacks a status word. In APDU responses specification it means "Incorrect P1 or P2 parameter. If an APDU command response pair has been defined for T=0 and it has both command data and response data (case 4S) then a separate TPDU will be generated to send and receive data (GET RESPONSE). An Application Protocol Data Unit (APDU) is simply a byte array that contains information following the ISO 7816 standard. when I try to add/modify its keys via JCManager I receive 6A84 and 6A88 APDU-Response. Note that the same list with extended searching options is implemented in our freeware BP-Tools product. Not Sure still looking to match APDU – Saravana Cd APDU - EMV, APDU command/response parse at iso8583. As you may know, Gloabal Platform Card Specification defines a command named Get Data to retrieve some information from the smart card. Unfortunately, I have not yet understood the meaning of the response of the CDF! Unfortunately I'm not able to get a APDU-Response from my card after sending any APDU-Command. APDU - GlobalPlatform, APDU command/response parse at iso8583. These commands are specified by NXP, the DESFire card manufacturer [10]. So: 0x00 0xA4 0x04 0x00 0x03 0xA0 0xA1 0xA2 Constructs a CommandAPDU from the four header bytes, command data, and expected response data length. command of APDU is as below. Card Risk Management Data Object List 1 (CDOL1) [8C]: Amount, Authorised (Numeric) [9F02]: Length: 06 Amount, Other (Numeric) [9F03]: Length: 06 Terminal An APDU is an Application Protocol Data Unit, a TPDU a Transport Protocol Data Unit. Each class will know what information is needed from the caller for that command. Therefore, the four traditional cases are redefined as follows: Case 1. 4, we have the possibility to create a Card Emulation Service, that will act as a Smart Card by taking APDU commands and returning APDU responses. simalliance. func send Command (apdu: NFCISO7816APDU, result Handler: (Result<NFCISO7816Response APDU, any Error>) -> Void) Sends an application protocol data unit (APDU) to the tag and receives a response APDU. 5 Logical channels. 7k 29 29 gold badges 180 180 silver badges 260 260 bronze badges. If you want to get the application list without authenticating, there is a slight chance that the following might work:. Why is the response this: CLA: 80, INS: b0, P1: 00, P2: 00, Lc: 00, Le: 06, 80, b0, 00, 00, 7f, f2, SW1: 90, SW2: 00 ? Thanks!!!! Comments. GPGlobalPlatform Card Specification. Open a logical channel : 00 70 00 P1 P2 LE Close a logical channel : 00 70 80 P1 P2 LE P1-P2 = 0000-0003 LE= 01(if P1-P2=0000) or Empty (if P1-P2!=0000)And the only open logical channel by default is Basic channel. As a first step you could try other class byte values, 0x00 (pure ISO) and 0xA0 (GSM-heritage) being the the most promising. Length Expected (LE): Specifies the expected length of the response data. indentSelect indent level. The APDU command consists of fields with a specific purpose. Here are results with EMV APDU command/response Command -> Response, Command -> Response, over and over. 1 states a generic structure of an Application Protocol Data Unit (APDU) that is used Application protocol data unit (APDU) is a command-response protocol for invoking functions executed on AmbiPay Smart card reader. ) The next command you send is an invalid SELECT (by EF) command: 00 A4 02 0C 01 01 00 I tried to use a custom byte array which contains the necessary values but I still get a 6A82 response code. Her ISO 7816 How to Use Calculate Signature Command APDU Multiple Times Hot Network Questions Credit Card Cash Back Points & Balance Transfers I am writing some code to send electronic identification cards using ISO-7816: If I send a "SELECT FILE" command: INFO: Send command PC -> SAM: 00 a4 04 00 0f a0 00 00 00 18 43 4d 08 09 0a 0b 0 I am trying to use run gsm algorithm command using RUIM tool. A estrutura da APDU é definida pela ISO/IEC 7816-4 Organization, security and commands for interchange (Organização, segurança e comandos 00 20 00 81 06 3x 3x 3x 3x 3x 3x --VERIFY response: 9000 00 A4 04 00 XX xx xx xx xx xx xx. SW1 and SW2 combined are the status word (SW). Any advice on what the problem might be. I tested the APDU commands with a Yubikey 4 : it works without problems. Delete command [CMD]80E40080074F050104070205. As you may know, Gloabal ISO 7816-4 Section 6 describes Basic Interindustry Commands. I have met the issue of response from APDU. g. 1 Unable to construct VERIFY_PIN_DIRECT control command. Hello NXP community, I'm working on PN5180 module to read data from my ePassport (ICAO 9303). This makes those products I’m developping following this reference guide, I try a simple HMAC-SHA1 Challenge/Response with APDU commands. But I tried all the numbers from 0-8 just in case, Reading a response of an APDU command. The data structure is as follows: Important: I am in a test environment, I am studying the APDU commands. Mark as New; Bookmark; Subscribe; Mute; Subscribe to RSS Feed; Permalink; Print; Email to a Friend; Report Inappropriate Content 2018-01 External commands are supported withRUN <command>. The CLA byte encoding is divided into two spaces: Interindustry —Used by all ISO/IEC 7816-4:2013- defined commands. something seams wrong with the "13" as this should be the length of the data to follow. As in short length, this case is not affected. Here is the sample for Generate AC APDU Command and Tag 0x80 Format 1 template in You would then wrap that data into the DATA field of the GENERATE AC command APDU: 80 AE 5000 1D 000000001000 000000000000 0040 0000000000 0978 150528 00 12345678 00 In response to this, you would either get a response message data field wrapped in tag 77 (format 2) that consists of several data objects. A response APDU is sent by the card to the reader — it contains from 0 to 65536 bytes of data, and 2 mandatory status bytes (SW1, SW2). APDU For Authenticate a Block:-The APDU format for Authenticate a block should be in following format. The Response APDU consists of two parts: the data field and the status field. You can request our support In the Get Processing Option (GPO) Command response BER-TLV encoded data. What am I doing APDU commands follow the ISO/IEC 7816-4:2013 specifications to encode logical channel information in the CLA byte. The first byte of our command APDU is taken up with a header called the class byte, abbreviated to CLA. Locked Post. The response TPDU is mapped onto the response APDU I want to read this through my Android based Point Of Sale systems which require going through PICC and APDU commands (so I can't use the default Android NDEF library). APDU commands are used to communicate with a smart card reader and perform various operations such as reading and writing data, authenticating the card, and managing the card's files. We manage to initialize the chip and to send an REQA command (We get 00 04 back from the card so communication works!). The first APDU (Application Protocol Data Unit) is the basic information unit used to transmit commands and responses between smart cards and devices. My current workflow is more or less the ISO 14443-4: Search for cards; receive ATQA; Perform anticollision and select card; Determine whether card is supporting ISO-14443-4 protocol or not; Send RATS and receive ATS The APDU protocol is the way how an NFC-Reader and NFC-Smart Card are going to communicate, it is an APDU message command-response pair, consisting of two pieces: a) The NFC-Reader is sending data by sending a command APDU to the NFC Smart Card. Table 8-6 specifies the field sequence in the Response APDU. Modified 9 years, 3 months ago. I am trying to read a file that is under MF. From a card reset, send the APDU 00A40400 to hopefully select the ISD. I am trying to use UPDATE BINARY command using APDU command for modify IMSI code, but The response is 98 04. Reading EMV card's serial number. Card readers may supports reader features management/control commands. Consequently, the semantic meanings of length fields and data fields in clauses 6 and 7 may seem in contradiction with their syntactic meanings in 5. APDU is abbreviation of Application Protocol Data Unit - these commands and responses mostly used to communicate with smartcards. Response APDU หรือ ชุดข้อมูลที่ส่งกลับมา This apdu crate declares some high-level APIs to compose APDU commands or parse their responses easily. 0 Your response code [106, -126] is better represented as hexadecimal, rather than implying any signed values. e. This APDU selects a DESFire Application by it’s three byte DESFire Application Identifier (DESFire AID). After testing questions I sent the command to verify the PIN containing an invalid PIN 3 times in a row. 6 Secure messaging. 2 Decoding convention for command bodies 5. CLS : 80. select the PSE Read Record Get processing options Read Record Get Challenge command Get Data command The response on the SELECT command for PSE contains FCI data object, which should looks according EMV Book 1 like: Tag. A step in an application protocol consists of sending a command, processing it in the receiving entity and sending back the response. APDU - UICC, APDU command/response parser at iso8583. the 01 should mean this directory has 1 sub-directory and the 15 should mean it has 0x15 files within it. 3 Pin verify command returns 90 00. struct NFCISO7816Response APDU. Add But when I send an APDU Command via SCardTransmit, i'll get 6E 00 as the answer from the card. ISO 7816-4 Section 6 - Basic Interindustry Commands; Complete list of APDU responses; Share. Data SW1 SW2; 7C 0A 81 08 <Client Authentication Challenge (8 bytes)> 90: 00: Command APDU Info (Second Call) CLA INS P1 P2 Lc Data Le; 00: 87: xx: 9B: 0C: 7C 0A 82 08 <Client Authentication Response (8 bytes)> (absent) Response APDU Info (Second Response) pn532 module connected to arduino nano via i2c protocol test sketch view uid card works when I try to send an APDU command to a command, I get an incomplete response or rather not even true. There are two categories of APDUs: command APDUs and response APDUs. let command = apdu::command::select_file( 0x12 , 0x34 , & [ 0x56 , 0x78 ]); let bytes: Vec<u8> = command. ; That last command comes from page 152 of the GlobalPlatform v2. If the UAF APDU command response contains the Tag "0x2813", the host must send a proprietary Get Response APDU command, otherwise the host must send the ISO CommandAPDU commandAPDU = new CommandAPDU(0x00, 0xA4, 0x00, 0x0C, new byte[]{0002},0,0x01); won't do what you expect it to do. Ask questions, find answers and collaborate at work with Stack Overflow for Teams. 4. supportThis tool can be developed when required. Data: 4F 05 C:\java_card_kit-2_2_2\gpj-20120310>". In essence, the command consists of a 4-byte Complete list of APDU responses. An object containing the response from the tag. A0 A4 00 00 02 3F 00 -> SELECT MF A0 A4 00 00 02 7F 20 -> Select DF_GSM A0 A4 00 00 02 6F 07 ->Select EF_IMSI A0 D6 00 00 09 [08 79 03 30 60 00 61 33 23] -> UPDATE IMSI FOR RANDOM NUMBER How to read smart cards chip and nfc data with apdu commands from the card reader. ISO 7816 4 defines answer to reset ATR historical byte structure, interindustry APDU commands for interchange and access methods to files and card data. I am trying to use run gsm algorithm command using RUIM tool. This clause contains SCardTransmit is designed to exchange commands with a smartcard, but commonly used cards (especially in the contactless world) are memory cards, and not smartcards. This class does not support extended length fields. I have retrieved the CDOL1 from the ICC data, however the card respond with 6985. In figure 5 a typical APDU command and response structure is I tried to select master file MF from contact card using APDU commands according to the ISO7816-4 instructions. 0 Structure and case. 1 MIFARE classic card APDU authentication failure. Note that when the expected length of the response APDU is specified in the constructors, the actual length (Ne) must be specified, not Im testing a dummy card with specific software for testing developed (not by me), but I'm getting this SW after a Select application command Command: 00A4040007A000000003101000 Status Word: 6982 - As far as I know, to open/close a logical channel we must use MANAGE CHANNEL APDU command. Everytime 6E 00. "0x63,0x64,0x63,0x00,0x00,0x00,0x00,0x32,0x32,0x31" was Android : NFC APDU command response '6700' Wrong length' Ask Question Asked 11 years, 8 months ago. 7. Now how do I actually send it to the receiving Android device which is using host card emulation. Get Data APDU command different tags and response format. 3. Boycott A. apdu. This A command APDU following the structure defined in ISO/IEC 7816-4. 6A82 corresponds to "Wrong parameter(s) P1 P2; file not found". I have a FEITIAN bR301 reader and i am trying to run the VERIFY APDU command but the result is 6a88 (Referenced data not found). How to decode ResponseAPDU to XML from an Austrian e-card? 4. What am I doing I have met the issue of response from APDU. A088 0000 10 Response APDU. Toggle Dismiss. 6. This method sets the state I'm trying to send a VERIFY (pin) command using javax. This class does not attempt to verify that the APDU encodes a semantically valid response. APDU response “90 00” – Command successfully executed (OK). The Response APDU is a data structure returned by a smart card to the interface device (such as a card reader or a mobile phone) after receiving and processing a Command APDU (C-APDU). Latest news Tools and modules NFC Handy Tools On site library Request our support. Command successfully executed; ‘XX’ bytes of data are available and can be requested using GET RESPONSE. Typically, the status word 6F00 means that your code throws an unhandled exception. ABSTRACT PC/SC is the de-facto standard to interface Personal Computers with Smart Cards (and smartcard readers of course). It contains the results of the requested operation or command. GlobalPlatformPro is one of the popular tools for communication with smart cards. APDU Byte Text Conversion: Converts APDU command byte text into a structured dictionary. The 3. Also I am surprised that some data is returned as response to ISOExternalAuthenticate command. Cause APDU = CLA,INS,P1,P2,AID. For any PICC/VICC but Mifare Classic, this instruction is executed without any prerequisite. The APDU object In the example above, we use the getBuffer() method to obtain the response from the reader and then process the response as needed. Sending a Command. In response to this command the card will send you a list of application IDs (AIDs) that it supports. My Pin code is 12345678. APDU specifications for READ BINARY, WRITE BINARY, UPDATE BINARY, ERASE BINARY, The GET RESPONSE command is used to transmit from the card to the interface device APDU(s) (or part of the APDUs) which otherwise could not be transmitted by the Command -> Response, Command -> Response, over and over. I have a created my HCE service to respond with a response APDU as in this thread: How to define an APDU for STORE DATA for Host Card Emulation? public static byte[] An APDU consists of a header and Body and understanding the structure of the APDUs is fundamental. A Response APDU is also sent in There are two categories of APDUs: command APDUs and response APDUs. protocol, this method will return 32767 when the Le field in the APDU command is protocol is 0x0000 or greater than 32767 and the currently selected applet implements the javacardx. HOW Your response code [106, -126] is better represented as hexadecimal, rather than implying any signed values. The command APDU is used to send commands from the card reader to the smart card, while the response APDU is used to send responses from the smart card to the pyResMan is a free open source smartcard tool for JavaCard and other smart card. Open a logical channel : 00 70 00 P1 P2 LE; Close a logical channel : 00 70 80 P1 P2 LE; P1-P2 = 0000-0003; This is output of Opensc-tool, and as you see, I successfully send and receive SELECT and GET RESPONSE commands and responses, The Get Response command is another command that allows the use of the T=0 link-level protocol for conveying the full range of APDUs. apdutool Examples This class only supports messages which conform to the structure of command and response defined in ISO 7816-4. jar -load . Viewed 4k times Part of Mobile Development Collective 0 I am sending below APDU command to ISODep tag and I am getting '6700 wrong length' Response also defined in GSM11. this method will return 32767 when the Le field in the APDU command is protocol is 0x0000 or greater than 32767 and the currently selected applet implements the javacardx. b) The NFC Smart Card answers the command by sending a response APDU to the NFC Reader. P1 : 00. PCSC Operation APDU Interpreter Standard instructions UPDATE BINARY April 13, 2023 at 2:39 AM #UPDATE BINARY instruction. You may switch to outbound data direction only once. It consists of a four byte header and a conditional body of variable length. I'm facing some problems with apdutool (javacard 2. The Card used is a NXP smart card. 5. It defines the fields and lengths of I tried to select master file MF from contact card using APDU commands according to the ISO7816-4 instructions. For Mifare Classic, to be able to read the Sending and Receiving Responses to APDU Commands using Proximity Device. List of APDU responses for EMV processing with their description. 11 Section 9. Based on some examples I've found on the net, I've tried with this APDU: 00 20 00 83 08 01 02 03 04 Note that, Security Domain and Card Manager (The entity responsible for answering to SELECT APDU Command), usually have equal responses for both interfaces. Important: I am in a test environment, I am studying the APDU commands. See EMV Book 1 for more details. 3. Process method does not receive full APDU command from host? 0. Class not supported. 3 Response APDU However, if Le is present in the command APDU, the data field of the response APDU is expected to consist of Le bytes. 00 20 00 81 06 3x 3x 3x 3x 3x 3x --VERIFY response: 9000 00 A4 04 00 XX xx xx xx xx xx xx. I don't get and response. Hot Network Questions Arrange the 15 The ISO 7816-4:2005 specification defines an extended APDU as any APDU whose payload data, response data or expected data length exceeds the 256 byte limit. How to get the UID from a DESFire (EV1) card depends on what type of ID you This list is also use by the online ATR parser at https://smartcard-atr. I have been trying to communicate with a EMV smart card on a MCR200 reader/writer hardware over a serial port using APDU commands but still no success. When I list the installed applets on the card using this tool, I have the following output:. 6) on the structures of APDU messages. openmobileapi successfully and my objective is achieved but moving forward to provide support for android devices with an api level more than 21 , i need to SELECT AID Response PDOL: 9F 1A 02 So I have to put the Terminal Country Code, in my case Italy: 380 So the GPO call is: 80 A0 00 00 04 83 02 03 80 00 I think You are in doubt to write a generic function to construct GPO APDU command. I've only seen it work on one card: the Tesla Model 3 NFC Specification of a protocol to transmit APDU commands and responses over Bluetooth Low Energy. Response trailer SW1 SW2 The secured command APDU is as follows. This class only supports messages which conform to the structure of command and response defined in ISO 7816-4. as follow: Initialized reader; Connect to the Card; Select MF -> [00 A4 00 00 02 00 3F] result [69 85] (Condition of use not satisfied) I think it there is a missing step before the selection command, please your advise A command APDU following the structure defined in ISO/IEC 7816-4. I can sen RATS - ATS, PPS, so technically, now i can exchange data using APDU command. The legacy case 2 from previous Java Card technology releases. A response APDU is sent by the card to the reader – it contains a mandatory 2-byte status word The APDU instruction interactive response has no response content, only a status code,How to solve it ?Thanks! Problem phenomenon: (Example) The testing sequence is a process of selecting files ->obtaining application ST25R3911B No Response Data After Sending APDU Command Go to solution. The response is 97 0C, but there is no data on Dataout. To Get all content of one certificate : GET RESPONSE : 00 B0 00 19 E7 00 B0 01 19 E7 00 B0 02 19 E7 00 B0 03 00 04. If the status word has the value 0x9000 (SW1 = 0x90, SW2=0x00), the command was successfully Note that, Security Domain and Card Manager (The entity responsible for answering to SELECT APDU Command), usually have equal responses for both interfaces. This document describes APDU commands and response codes used for smart card communication. In other words, I have proven working Java Card commands. Explore Teams Create a free Team I began to study basic notions of APDU command and response these days and i'm in a doubt about the use of the Lc and data track and his meaning. Firstly, i tried to select LDS1 but however i tried, i always get SW1 SW2 = 0x67 0x00, which means "Wrong length". So let’s break down a simple APDU as it appears on the wire, so to speak. See chapter 12. Presence. Improve this answer. 1. 02 means its a DF (Folder). The highest bit (bit 8 in ISO 7816) is high, which means this is a non-standard APDU. It actually would be 6A82 - which forms SW1 and SW2 of the APDU Response Code. --SIGN response: 6a88 In the last command, the expected response would be: HASH_SIGNED + 9000. I. Drop-down menu with pre-configured APDU commands. exe" -jar gpj. 33 APDU Basic Commands - Free download as PDF File (. cap -install -list Found terminals: [PC/SC terminal Gemplus USB SmartCard Reader 0] Found card in terminal: Gemplus USB SmartCard So, when I launched the following APDU command, I've obtained the content of my certificate: SELECT FILE : 00 A4 00 0C 02 B0 01. Proprietary — Used by Java Card technology to encode application- specific commands No contexto de cartões inteligentes, uma application protocol data unit (APDU), em português unidade de dados de protocolo de aplicativo, é a unidade de comunicação entre um leitor de cartão inteligente e um cartão inteligente. The command i am using is. scriptor. For Example: FF CA FA 00 00 (Card's ATR - Answer To Reset) or; FF CA FF 82 00 (Product name in ASCII) The same thing when i send the Command with an PC/SC Testtootl like "PC/SC Diag". I. Note that when the expected length of the response APDU is specified in the constructors, the actual length (Ne) must be specified, not This is my question: if my first apdu command were: 0x80 0xB0 0x00 0x00 0x00 0x7F; where "Le" i think that it must be 0. 6F. setOutgoingAndSend() is mutually exclusive. How to pass any APDU command from currently selected applet to another applet? 4. I tried inserting a fake P3 (Lc), but I always get ParseException errors. Also, the ,0,0x01); (last two parameters) will make the constructor only pick that one byte from the DATA array. Stack Overflow for Teams Where developers & technologists share private knowledge with coworkers; Advertising & Talent Reach devs & technologists worldwide about your product, service or employer brand; OverflowAI GenAI features for Teams; OverflowAPI Train & fine-tune LLMs; Labs The future of collective knowledge sharing; About the company This apdu crate declares some high-level APIs to compose APDU commands or parse their responses easily. I'm trying to read the data off a contactless Mastercard Paypass card. You can request our support I have a java card that is empty of applets. 256, in the response APDU. Le set to '00' indicates that the terminal expects to receive at most the maximum number of bytes, i. 1 of ISO/IEC 7816-3 (2006). For example you can change the color of the LED, or delay Reading a response of an APDU command. as follow: Initialized reader; Connect to the Card; Select MF -> [00 A4 00 00 02 00 3F] result [69 85] (Condition of use not satisfied) I think it there is a missing step before the selection command, please your advise No response data) and Case4Short (Command data. txt) or read online for free. It consists of a conditional body and a two byte trailer. How can I understand APDU commands? Answer: When you write an applet, you specify the response of your applet to different APDU commands that it will receive in the future. Response APDU. SpringCard PC/SC Readers comply with this standard. The command APDU is mapped onto the T=0 command TPDU by assigning the value ’00’ to P3. INS : E4. So your APDU will look like this: This class only supports messages which conform to the structure of command and response defined in ISO 7816-4. AEIPSAmerican Express ICC Payment Specification. Read Record command parameters. SmartCard APDU Request data for First Generate AC Command contained Series of Values mentioned in CDOL1. fr/ to report it. I've only seen it work on one card: the Tesla Model 3 NFC . Using reader: "Yubico Yubikey 4 CCID 0" Sending APDU: "00a4040008a000000527200101" APDU response: "040301030300010f00009000" Sending APDU command หรือชุดคำสั่ง เพื่อทำการส่งไปยัง Smart card ที่ต้องการให้ Smart card ส่งกลับมา ในส่วนของ Response APDU ซึ่งจะอธิบายต่อไป . ; User-Friendly: Designed with a focus on simplicity and ease of use, making it accessible for both beginners and experienced developers. --SELECT APP response: 9000 00 22 41 B6 06 80 01 8A 84 01 81 --SECURITY ENVIRONMENT response: 9000 00 2A 9E 9A XX xx xx xx xx xx xx. – Farhan Nasim I'm constructing a generate AC command for a Mastercard contactless card. Provide details and share your research! But avoid . 0 SunPCSC - don't issue GET RESPONSE commands: sc -no-get-response -a 00A4040000 -v Show APDU-s sent to the card (using LoggingCardTerminal): add -debug or -d to your command. UICCUnionPay Integrated Circuit Card Specifications. length) long. In this case it confirms the selection of the “NFC NDEF tag app”. Example of a Command APDU (for collecting data from a smart card):CLA INS P1 P2 LE FF CA 00 00 00; Response APDU (R-APDU): Sent by the smart card in response to a Command APDU. 2 distribution) in executing the 'Get Response' command. A0 A4 00 00 02 3F 00 -> SELECT MF A0 A4 00 00 02 7F 20 -> Select DF_GSM A0 A4 00 00 02 6F 07 ->Select EF_IMSI A0 D6 00 00 09 [08 79 03 30 60 00 61 33 23] -> UPDATE IMSI FOR RANDOM NUMBER This class only supports messages which conform to the structure of command and response defined in ISO 7816-4. The host shall support both versions of Get Response APDU command, and figure out which command must be sent to the Applet by parsing the response of the UAF APDU command. That is, you can't send a body of data to the card and then receive a body of data back as a direct response to that command. info. External commands are useful to make mini scripts that depend on input/output sequence. For example, if i write a command like: 00 A4 04 00 0E 31 50 41 59 2E 53 59 53 2E 44 44 46 30 31 00 I'd say that his (correct me case if i'm wrong) ISO/IEC 7816 part 4 smart card standard specifies the contents of messages, commands, and responses transmitted by APDU. Clauses 6 and 7 do not describe the impact of secure messaging (see 5. About site services Guides at YouTube. Case 2S. In the Get Processing Option (GPO) Command response BER-TLV encoded data. DIR file. At least i want to start with getting the ATR of the card before proceeding to reading and writing records to the smart card. This section includes the following topics: Running apdutool. I wanna know the mechanism in which the card returns 1000-bytes data in case 4. Therefore a spcecific response corresponds to a specific command, referred to as a command-response pair. The behavior of messages which use proprietary structure of messages is undefined. It can be used to send APDU(s), execute APDU script(s); It can be used to debug ISO14443 protocol commands and Mifare commands with R502 SPY reader; It can also be used to manage resource of GP card, It is based on pyScard and GlobalPlatform open source projects. 1 Data structures. Original PIN: 1574 Starting from Android 4. Hence, the use of apdu. Verify APDU command is : CLA = 0x00 INS = 0x20 P1 = 0x00 P2 = 0x00 LC = 0x08 0x20 0xff 0xff 0xff 0xff 0xff 0xff 0xff After this i enter pin on pinpad, then i receive APDU response 6a86. Now you have execute Authentication command and you overwrite the block 3(sector trailer) that means the keys and access right has been change. smartcardio API. A ISO 7816-4 Section 6 describes Basic Interindustry Commands. It is cross-platform now, but some os-specific features can be added in the future. DDF01. answered Aug 14, 2018 at 22:45. MIFARE or to sent a command to the reader (as opposed to the card); there is considerable overlap of this possibilities. The presented on-site APDU parsing tools breakdown the generic data fields of ISO7816 and add fields dissections related to the yes, You have to authenticate every sector before read/write on the block of that sector. Optionally, apdutool can write this information to a log file. SYS. Specifically, the Case 4 type of APDU body cannot be supported with the T=0 protocol. The Command APDU contains a header that specifies the type of command being sent, such as read or write 5. Lc : 07. Hot Network Questions Theory of truth involving a virtual omniscient being The unsecured command-response pair is as follows. Here is what i have tried so far. An extended APDU is an APDU (command) with data and/or response of more than 256 bytes and up to 65536 bytes. I want to select the appropriate AID application with the command: 0x00, 0xA4, 0x04, 0x00, 0x0E, 0x32, 0x50, 0x41, 0x59, 0x2E, 0x53, 0x59, 0x53, 0x2E, 0x44, 0x44, PMD841P-FA page 6 of 86 SPRINGCARD PC/SC READERS - CSB6 GROUP - APDU interpreter and vendor-specific commands 1. INTRODUCTION 1. If your ATR is not already in the list then please use https://smartcard-atr. The length Le is also null; therefore the Le Parameter 2 Byte (P2): Optional data or parameters needed for the command. Some questions about SELECT APDU command in Javacards. 2. Card A Response APDU is sent by the smart card in response to a Command APDU. The UPDATE BINARY instruction writes data into a memory card (wired-logic PICC or VICC). I am working on NFC enabled SIM, using ISO-7816-4. . Where data is passed in or out via byte arrays, defensive cloning is performed. While I try to SELECT MF, DF or EF, response is always 6A 82( File not found). The behavior of messages which use proprietary structure of messages ( for example with header CLA byte in range 0xD0-0xFE ) is undefined. b) External Authenicate. A Response APDU is sent as a response by the on-card installer after each APDU that it receives. fr/. Associate III Options. basically its saying the id is 7FF0. Instances of this class are immutable. APDU Command and Response Flow for ISO 14443-Compliant Tags. Otherwise it is a short APDU. Marius Celliers. For example its: 0xFF, 0xCA, 0x00, 0x00, 0x00 but result of this command is: 6E 00, that on specifications of APDU answers tell that "Class not supported" Then I found that its APDU command may be as: 0x00, 0xCA, 0x00, 0x00, 0x00 this command return 6A 88 As the APDU commands should be given in a format, There are four cases to be followed , when sending commands to APDU: Case Command data Expected response data 1 No data No data 2 No data Data 3 Data No data 4 Data Data In case 1, the length Lc is null; therefore the Lc field and the data field are empty. Ask Question Asked 7 years, 4 months ago. My PIN is "012345" and based on some examples my command APD This apdu crate declares some high-level APIs to compose APDU commands or parse their responses easily. Asking for help, clarification, or responding to other answers. Following are the APDUs 00 A4 00 00 02 3F 00 -> To SELECT MF 00 A It is a SELECT (0xA4) by AID (0x04), where 0x0C indicates that no response needs to be send, followed by Lc, which encodes the Nc, the size of the command data (0x07). How to identify card number,expiry date, cvv, card holder name from from read record result. The value Nc is taken as dataLength. I record a lot of data but since there's only one line for command and response, I get a load of hex data with no boundary in between. Value. My PIN is "012345" and based on some examples my command APDU is: The AID of my app is F239856324897348 and I have constructed a SelectAID APDU for it. The APDU object These commands are specified by NXP, the DESFire card manufacturer [10]. I might be having some problems with understanding the P2 parameter (the OFFSET). 1 Command APDU. APDUs, on the other hand, are exchanged on a higher protocol layer and only after activation of the card. FF 82 00 60 06 FF FF FF FF FF FF response - 9000 However authentication command always fails. APDU specifications for READ BINARY, WRITE BINARY, UPDATE BINARY, ERASE BINARY, READ RECORD(S), WRITE RECORD, APPEND RECORD, UPDATE RECORD, GET DATA, PUT DATA, SELECT FILE, VERIFY, INTERNAL AUTHENTICATE, EXTERNAL AUTHENTICATE, A step in an application protocol consists of sending a command, processing it in the receiving entity and sending back the response. This will execute APDUs printed on command's standard output as hex strings, line by line, passing full response hex string (including sw1 and sw2 bytes) to command's standard input. P2 : 80. cap file. parsing The apdutool reads a script file containing APDUs and sends them to the simulator or another Java Card RE. So: 0x00 0xA4 0x04 0x00 0x03 0xA0 0xA1 0xA2 I can successfully load keys using below command. The functionality of the ISO SELECT DIRECTORY Command is compatible with the native DESFire “Select Application” command. 1. Menu. prototype protocol apdu bluetooth-low-energy fidesmo apdu-commands Updated Dec 12, 2018; CodElecCz / STM32F1-CLRC663 Star 7. I read couple of explanations, but still don't get what OFFSET do they mean. In your sample: Under Tag 0x80 "Template, Response Message Format 1" packed Tag 0x82 "EMV, Application Interchange Profile (AIP)" value 2 bytes and rest is Tag 0x94 "EMV, Application File Locator (AFL)" value. length,AID. Hi all, I have a FEITIAN BR301 reader and i am trying to run the VERIFY APDU command but the result is 6a88 (Referenced data not found). Command header bodv Response APDU Info (First Response) Total Length: 14 Data Length: 12. I got the file's SFID, so I don't use the method SELEC_FILE first (since it's not necessary). In your case, this could be caused by the use of both apdu. CDOL2 used for Second Generate AC. 2 MIFARE Classic 1K load authentication keys failure with ACR122U. The EF. Unfortunately, I have not yet understood the meaning of the response of the CDF! The APDU you give looks more like the pseudo-APDU to address non-processor card as e. So I submit a SELECT PPSE command using 2PAY. Data: 4F 05 I can successfully load keys using below command. When no indication is given in the data coding byte, the logical OR behavior shall apply. Based on some examples I've found on the net, I've tried with this APDU: 00 20 00 83 08 01 02 03 04 OATH commands and APDUs. setOutgoing() and apdu. Send APDU commands to USIM/SIM card in android. Reading a response of an APDU command. Response trailer Empty New SW1 SW2 Response body Data field . Use APDU commands to get some information for a card. I can I have met the issue of response from APDU. scriptor(1) is a Perl script to send commands to a smart card using a batch file or stdin. What is meaning of the response status word 0x61xx from a smart card? 4. There are two types of APDUs: command APDUs and response APDUs. The response APDU has an optional body consisting of data and a mandatory trailer with two status bytes "SW1" and "SW2". Current page is NFCISO7816APDU Apple. The APDU object is owned by the Java Card runtime environment. APDU was originally defined An APDU consists of either a command message or a response message, which are sent from the interface device to the card or vice versa. \Program Files\Java\jre6\bin\java. I'm confused about Get Response command. Contribute to eIDuy/apdu-parser development by creating an account on GitHub. A specific command message sent by the terminal (C-APDU) will have a specific response message from the card (R-APDU). A response APDU as defined in ISO/IEC 7816-4. setOutgoingAndSend(). If Ne or Nc are zero, the APDU is I am done with Mutual Authentication Command : a) Initialize update . bbvfv wpdrix ptqjc ttakpb aaclvn jyjqx tfwqv vcklc repkqntkd xef